FEATURED PROJECT

United States Aluminum's Defender Series BT601 Storefront System Bridges The Gap Between Blast Mitigation And Hurricane Resistant Systems

 

01.01.2010


Waxahachie, Texas, Jan 1, 2010 — Today United States Aluminum unveils the Defender Series BT601 Storefront System, a versatile thermally improved product that can be used in a blast mitigation environment, a hurricane resistant environment, or even a condition that requires a system to meet both specifications.

bt601In its primary configuration as a thermally improved blast mitigation system, the BT601 can be specified for up to a 1psi blast load. BT601 is tested in accordance with both DOD UFC and Dade County Protocols to make the product applicable for blast mitigation projects in HVHZ coastal regions. Thermal efficiency, a driving design requirement from the beginning, is accomplished using our pour and debridge thermal barrier. The thermal improvement combined with the insulated glass produces a system compliant with the U.S. Department of Energy's Building Energy Codes Program.

The BT601 storefront system features a 2 ½” x 5” profile, a high performance subsill, and is designed to be glazed with 1 5/16” impact resistant insulated glass. Screw spline assembly allows units to be shop fabricated for quicker, easier field installation. Available finishes include a wide selection of standard paint colors, custom matched painted coatings, and a selection of clear, bronze or black anodic finishes.

The BT601 Entrance incorporates a patented one glazing bead design ensuring maximum protection at the entrance area. Standard corner construction includes heavy duty blocks and welding for secure door corners.

The BT601 Storefront system is tested to meet or exceed specifications:
ASTM E 283-91
ASTM E 331-00
ASTM E 330-02
ASTM E 1886-05 E 1996-05
ASTM E 283-04
Dade County Protocol PA 201-94
Dade County Protocol PA 202
Dade County Protocol PA 203
ISC - Security Design Criteria Blast Protection for Windows
GSA Condition 1 & 2
DOD - ATFP
UFC 4-010-01 - Jan 07
DOE Building Energy Codes Program - ANSI/ASHRAE/IESNA Standard 90.1-2010

The product manager for the Defender Series BT601 storefront system, Chris Gall, has been traveling extensively presenting the new system to architects across the country. Contact Chris Gall for in depth product information on the BT601, along with any of our blast mitigation products (tel: 803-323-5576, fax: 800-841-8722, email: chrisgall@usalum.com).

For a rendering of the BT601 system click here

For additional information, Contact: Gary Taylor, Marketing Manager, United States Aluminum, 972-937-9651 ext 537, fax: 1-800-289-6440, garytaylor@usalum.com, www.usalum.com

About United States Aluminum
United States Aluminum offers a full range of aluminum entrance doors, storefronts, curtain walls, windows, hurricane & blast mitigation systems, ribbon walls and sun control systems. As an industry leader since 1957, United States Aluminum has earned a well respected name as a supplier to the commercial construction industry.


# # #

 

Surrey City Hall
Surrey, BC

Products:
Series 7200 Window
Series 3250 Curtain Wall